Case study · Food processing · Compressed air
Base-plus-trim control cut compressor energy by a quarter, 491.77 to 368.25 kWh a day.
- Industry
- Parboiled rice mill
- System
- Compressed air
- Data used
- Per-feeder energy monitoring, compressor control log
491.77 → 368.25 kWh/dayCompressor feeder energy
−25%about 44,468 kWh a year
about ₹3.01 lakha year
What was found
The mill’s two compressors, 50 HP and 20 HP, both ran part-loaded, with neither acting as a stable base.
What was done
The 50 HP unit was set as base and the 20 HP unit as no-bleed trim, with tuned load and unload setpoints. It was a zero-cost change.
Cost and benefit
| Before | 491.77 kWh/day |
|---|---|
| After | 368.25 kWh/day |
| Energy saved | about 44,468 kWh a year (−25%) |
| Money saved | about ₹3.01 lakh a year |
More case studies
- Food processing · Power factor
A repaired capacitor bank, measured on its own feeder.
Daily feeder energy fell from 199.94 to 60.87 kWh after the repair.Measured on the feeder · about ₹3.43 lakh a yearRead the case study - Sugar cogeneration · Early warning
A turbine gearbox heading the wrong way, about two years early.
Bearing vibration crept up all year while every reading stayed inside the ISO good band.Measured trend · early warning, no saving claimedRead the case study - Hotel · Chillers
A 2 °C setpoint change. About 550 units a day.
Chilled water was reset from 7 °C to 9 °C, with guest comfort checked and held.Reported by the site · about ₹14 lakh a yearRead the case study
See it on your own plant.
No monitoring yet?
Zerowatt Vitals
Zerowatt Vitals puts every meter, sensor and machine in the facility live on one platform. Start with one system and add the rest as you go.
Already have monitoring?
Zerowatt Digital Brain
Zerowatt Digital Brain works on your existing monitoring system, DCS, SCADA or historian. Share your historian data and get your findings report.
zerowatt.energy · [email protected] · +91 80313 39988